Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Anal Chem ; 96(17): 6764-6773, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38619911

RESUMEN

Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.


Asunto(s)
Separación Celular , Técnicas Analíticas Microfluídicas , Humanos , Separación Celular/instrumentación , Separación Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Porosidad , Dimetilpolisiloxanos/química , Dispositivos Laboratorio en un Chip , Polimetil Metacrilato/química
2.
J Endourol ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38545752

RESUMEN

Purpose: We herein describe the superficial preprostatic vein (SPV) anatomy and determine its relationship with the accessory pudendal artery (APA). Materials and Methods: We reviewed 500 patients with localized prostate cancer who underwent conventional robot-assisted radical prostatectomy between April 2019 and March 2023 at our institution. SPV was defined as "any vein coming from the space between the puboprostatic ligaments and running within the retropubic adipose tissue anterior to the prostate toward the vesical venous plexus or pelvic side wall." While APA was defined as "any artery located in the periprostatic region running parallel to the dorsal vascular complex and extending caudal toward the anterior perineum." The intraoperative anatomy of each SPV and APA was described. Results: SPVs had a prevalence rate of 88%. They were preserved in 252 men (58%) and classified as I-, reversed-Y (rY)-, Y-, or H-shaped (64%, 22%, 12%, and 2%, respectively) based on their intraoperative appearance. Overall, 214 APAs were found in 142 of the 252 men with preserved SPV (56%; 165 lateral and 50 apical APAs in 111 and 41 men, respectively). SPVs were pulsatile in 39% men perhaps due to an accompanying tiny artery functioning as a median APA. Pulsations seemed to be initially absent in most SPVs but become apparent late during surgery possibly due to increased arterial and venous blood flow after prostate removal. Pulsations were common in men with ≥1 APA. Conclusions: This study, which described the anatomical variations in arteries and veins around the prostrate and their preservation techniques, revealed that preserving this vasculature may help preserve postprostatectomy erection. ClinicalTrials: The Clinical Research Registration Number is 230523D.

3.
J Robot Surg ; 18(1): 25, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217741

RESUMEN

OBJECTIVES: Patients with inguinal hernia (IH) may have voiding dysfunction and weak urethra-stabilizing periurethral fascial tissues, contributing to urinary incontinence. This study aimed to review the association between IH and urinary continence after robotic-assisted radical prostatectomy (RARP). METHODS: This single-institution retrospective study included 251 consecutive cases of RARP between April 2019 and June 2022. Patients with concurrent IH or a history of adult IH repair were examined. The urine loss rate (ULR), defined as 24-h urine loss volume divided by the total urine volume immediately after urinary catheter removal (i.e., 6 or 7 postoperative days), was compared between the groups with (n = 33) and without IH (n = 214). Possible contributing factors for ULR were assessed, including age, body mass index (BMI), after benign prostatic hyperplasia surgery, prostate weight, and nerve-sparing. ULR was compared intergroup after propensity score matching countering selection biases. RESULTS: Patients with IH were older (71.3 versus. 66.8 years, p < 0.01), had lower BMI (22.8 versus. 24.3, p < 0.01), and had higher ULR (14.5% versus. 5.1%, p < 0.01). In a multiple linear regression analysis (adjusted R2 = 0.084), IH (p < 0.01) was an independent contributing factor for ULR besides advancing age (p < 0.03). After propensity score matching adjusted for patient's age and nerve-sparing, patients with IH had higher ULR (14.1% versus. 5.7%, p < 0.03) as well. CONCLUSIONS: This study first reported that IH may be one of the risk factors of urinary incontinence after RARP.


Asunto(s)
Hernia Inguinal , Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Robótica , Incontinencia Urinaria , Masculino , Adulto , Humanos , Próstata , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Hernia Inguinal/cirugía , Incontinencia Urinaria/etiología , Incontinencia Urinaria/cirugía , Prostatectomía/efectos adversos , Neoplasias de la Próstata/cirugía
4.
Lab Chip ; 24(2): 171-181, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38050757

RESUMEN

Although droplet microfluidics has been studied for the past two decades, its applications are still limited due to the low productivity of microdroplets resulting from the low integration of planar microchannel structures. In this study, a microfluidic system implementing inverse colloidal crystals (ICCs), a spongious matrix with regularly and densely formed three-dimensional (3D) interconnected micropores, was developed to significantly increase the throughput of microdroplet generation. A new bottom-up microfabrication technique was developed to seamlessly integrate the ICCs into planar microchannels by accumulating non-crosslinked spherical PMMA microparticles as sacrificial porogens in a selective area of a mold and later dissolving them. We have demonstrated that the densely arranged micropores on the spongious ICC of the microchannel function as massively parallel micronozzles, enabling droplet formation on the order of >10 kHz. Droplet size could be adjusted by flow conditions, fluid properties, and micropore size, and biopolymer particles composed of polysaccharides and proteins were produced. By further parallelization of the unit structures, droplet formation on the order of >100 kHz was achieved. The presented approach is an upgrade of the existing droplet microfluidics concept, not only in terms of its high throughput, but also in terms of ease of fabrication and operation.

5.
Lab Chip ; 23(9): 2257-2267, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37038847

RESUMEN

Spheroid formation assisted by microengineered chambers is a versatile approach for morphology-controlled three-dimensional (3D) cell cultivation with physiological relevance to human tissues. However, the limitation in diffusion-based oxygen/nutrient transport has been a critical issue for the densely packed cells in spheroids, preventing maximization of cellular functions and thus limiting their biomedical applications. Here, we have developed a multiscale microfluidic system for the perfusion culture of spheroids, in which porous microchambers, connected with microfluidic channels, were engineered. A newly developed process of centrifugation-assisted replica molding and salt-leaching enabled the formation of single micrometer-sized pores on the chamber surface and in the substrate. The porous configuration generates a vertical flow to directly supply the medium to the spheroids, while avoiding the formation of stagnant flow regions. We created seamlessly integrated, all PDMS/silicone-based microfluidic devices with an array of microchambers. Spheroids of human liver cells (HepG2 cells) were formed and cultured under vertical-flow perfusion, and the proliferation ability and liver cell-specific functions were compared with those of cells cultured in non-porous chambers with a horizontal flow. The presented system realizes both size-controlled formation of spheroids and direct medium supply, making it suitable as a precision cell culture platform for drug development, disease modelling, and regenerative medicine.


Asunto(s)
Microfluídica , Esferoides Celulares , Humanos , Hepatocitos , Perfusión , Hígado
6.
J Biosci Bioeng ; 135(5): 417-422, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36931921

RESUMEN

Technologies for efficiently expanding Chinese hamster ovary (CHO) cells, the primary host cells for antibody production, are of growing industrial importance. Various processes for the use of microcarriers in CHO suspension cultures have been developed, but there have been very few studies on cell-adhesive microcarriers that are similar in size to cells. In this study, we proposed a new approach to suspension cultures of CHO cells using cell-sized condensed and crosslinked gelatin microparticles (GMPs) as carriers. Unlike commercially available carriers with sizes typically greater than 100 µm, each cell can adhere to the surface of multiple particles and form loose clusters with voids. We prepared GMPs of different average diameters (27 and 48 µm) and investigated their effects on cell adhesion and cluster formation. In particular, small GMPs promoted cell proliferation and increased IgG4 production by the antibody-producing CHO cell line. The data obtained in this study suggest that cell-sized particles, rather than larger ones, enhance cell proliferation and function, providing useful insights for improving suspension-culture-based cell expansion and cell-based biologics production for a wide range of applications.


Asunto(s)
Técnicas de Cultivo de Célula , Gelatina , Cricetinae , Animales , Cricetulus , Células CHO , Proliferación Celular
7.
Sci Rep ; 12(1): 22354, 2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-36572667

RESUMEN

Tsunamis are commonly generated by earthquakes beneath the ocean floor, volcanic eruptions, and landslides. The tsunami following the Tonga eruption of 2022 is believed to have been excited by atmospheric pressure fluctuations generated by the explosion of the volcano. The first, fast-traveling tsunami was excited by Lamb waves; however, it has not been clarified observationally or theoretically which type of atmospheric fluctuations excited more prominent tsunami which followd. In this study, we investigate atmospheric gravity waves that possibly excited the aforementioned subsequent tsunami based on observations and atmosphere-ocean coupling simulations. The atmospheric fluctuations are classified as Lamb waves, acoustic waves, or gravity waves. The arrival time of the gravity wave and the simulation shows that the gravity wave propagated at a phase speed of 215 m/s, coinciding with the tsunami velocity in the Pacific Ocean, and suggesting that the gravity wave resonantly excited the tsunami (Proudman resonance). These observations and theoretical calculations provide an essential basis for investigations of volcano-induced meteotsunamis, including the Tonga event.

8.
Analyst ; 147(8): 1622-1630, 2022 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-35297918

RESUMEN

Numerous attempts have been made to develop efficient systems to purify trace amounts of circulating tumor cells (CTCs) from blood samples. However, current technologies are limited by complexities in device fabrication, system design, and process operability. Here we describe a facile, scalable, and highly efficient approach to physically capturing CTCs using a rationally designed microfluidic isolator with an array of microslit channels. The wide but thin microslit channels with a depth of several micrometers selectively capture CTCs, which are larger and less deformable than other blood cells, while allowing other blood cells to just flow through. We investigated in detail the effects of the microchannel geometry and operating parameters on the capture efficiency and selectivity of several types of cultured tumor cells spiked in blood samples as the CTC model. Additionally, in situ post-capture staining of the captured cells was demonstrated to investigate the system's applicability to clinical cancer diagnosis. The presented approach is simple in operation but significantly effective in capturing specific cells and hence it may have great potential in implementating cell physics-based CTC isolation techniques for cancer liquid biopsy.


Asunto(s)
Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Línea Celular Tumoral , Separación Celular/métodos , Humanos , Técnicas Analíticas Microfluídicas/métodos , Microfluídica , Células Neoplásicas Circulantes/patología
9.
J Biosci Bioeng ; 133(3): 265-272, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34903469

RESUMEN

Numerous attempts have been made to organize isolated primary hepatocytes into functional three-dimensional (3D) constructs, but technologies to introduce extracellular matrix (ECM) components into such assemblies have not been fully developed. Here we report a new approach to forming hepatocyte-based 3D tissues using fibrillized collagen microparticles (F-CMPs) as intercellular binders. We created thick tissues with a thickness of ∼200 µm simply by mixing F-CMPs with isolated primary rat hepatocytes and culturing them in cell culture inserts. Owing to the incorporated F-CMPs, the circular morphology of the formed tissues was stabilized, which was strong enough to be manually manipulated and retrieved from the chamber of the insert. We confirmed that the F-CMPs dramatically improved the cell viability and hepatocyte-specific functions such as albumin production and urea synthesis in the formed tissues. The presented approach provides a versatile strategy for hepatocyte-based tissue engineering, and will have a significant impact on biomedical applications and pharmaceutical research.


Asunto(s)
Colágeno , Hepatocitos , Animales , Técnicas de Cultivo de Célula , Supervivencia Celular , Células Cultivadas , Ratas , Ingeniería de Tejidos/métodos
10.
Mater Sci Eng C Mater Biol Appl ; 129: 112417, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34579926

RESUMEN

Artificial biological scaffolds made of extracellular matrix (ECM) components, such as type I collagen, provide ideal physicochemical cues to various cell culture platforms. However, it remains a challenge to fabricate micrometer-sized ECM materials with precisely controlled morphologies that could reconstitute the 3-dimensional (3D) microenvironments surrounding cells. In the present study, we proposed a unique process to fabricate fragmented collagen microfibers using a microfluidic laminar-flow system. The continuous flow of an acidic collagen solution was neutralized to generate solid fibers, which were subsequently fragmented by applying a gentle shear stress in a polyanion-containing phosphate buffer. The morphology of the fiber fragment was controllable in a wide range by changing the type and/or concentration of the polyanion and by tuning the applied shear stress. The biological benefits of the fragmented fibers were investigated through the formation of multicellular spheroids composed of primary rat hepatocytes and microfibers on non-cell-adhesive micro-vessels. The microfibers enhanced the survival and functions of the hepatocytes and reproduced proper cell polarity, because the fibers facilitated the formation of cell-cell and cell-matrix interactions while modulating the close packing of cells. These results clearly indicated that the microengineered fragmented collagen fibers have great potential to reconstitute extracellular microenvironments for hepatocytes in 3D culture, which will be of significant benefit for cell-based drug testing and bottom-up tissue engineering.


Asunto(s)
Colágeno , Microfluídica , Animales , Matriz Extracelular , Hepatocitos , Polielectrolitos , Ratas , Ingeniería de Tejidos
11.
ACS Omega ; 5(34): 21641-21650, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32905425

RESUMEN

Although many types of technologies for hydrogel-based cell cultivation have recently been developed, strategies to integrate cell-adhesive micrometer-sized supports with bulk-scale hydrogel platforms have not been fully established. Here, we present a highly unique approach to produce cell-adhesive, protein-based microfibers assisted by the sacrificial template of alginate; we applied these fibers as microengineered scaffolds for hydrogel-based cell encapsulation. Two types of microfluidic devices were designed and fabricated: a single-layered device for producing relatively thick (Φ of 10-60 µm) alginate-protein composite fibers with a uniform cross-sectional morphology and a four-layered device for preparing thinner (Φ of ∼4 µm) ones through the formation of patterned microfibers with eight distinct alginate-protein composite regions. Following chemical cross-linking of protein molecules and the subsequent removal of the sacrificial alginate from the double-network matrices, microfibers composed only of cross-linked proteins were obtained. We used gelatin, albumin, and hemoglobin as the protein material, and the gelatin-based cell-adhesive fibers were further encapsulated in hydrogels together with the mammalian cells. We clarified that the thinner fibers were especially effective in promoting cell proliferation, and the shape of the constructs was maintained even after removing the hydrogel matrices. The presented approach offers cells with biocompatible solid supports that enhance cell adhesion and proliferation, paving the way for the next generation of techniques for tissue engineering and multicellular organoid formation.

12.
Anal Chem ; 92(3): 2580-2588, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-31822057

RESUMEN

Visualization and quantification of intracellular molecules of mammalian cells are crucial steps in clinical diagnosis, drug development, and basic biological research. However, conventional methods rely mostly on labor-intensive, centrifugation-based manual operations for exchanging the cell carrier medium and have limited reproducibility and recovery efficiency. Here we present a microfluidic cell processor that can perform four-step exchange of carrier medium, simply by introducing a cell suspension and fluid reagents into the device. The reaction time period for each reaction step, including fixation, membrane permeabilization, and staining, was tunable in the range of 2 to 15 min by adjusting the volume of the reaction tube connecting the neighboring exchanger modules. We double-stained the cell nucleus and cytoskeleton (F-actin) using the presented device with an overall reaction period of ∼30 min, achieving a high recovery ratio and high staining efficiency. Additionally, intracellular cytokine (IL-2) was visualized for T cells to demonstrate the feasibility of the device as a pretreatment system for downstream flow-cytometric analysis. The presented approach would facilitate the development of laborless, automated microfluidic systems that integrate cell processing and analysis operations and would pave a new path to high-throughput biological experiments.


Asunto(s)
Automatización , Citocinas/análisis , Técnicas Analíticas Microfluídicas , Animales , Línea Celular , Núcleo Celular/química , Núcleo Celular/metabolismo , Citocinas/biosíntesis , Citoesqueleto/química , Citoesqueleto/metabolismo , Diseño de Equipo , Citometría de Flujo/instrumentación , Ratones , Técnicas Analíticas Microfluídicas/instrumentación , Células 3T3 NIH
13.
Anal Chem ; 91(21): 13377-13382, 2019 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-31585029

RESUMEN

Lateral flow immunoassay devices have revolutionized the style of on-site disease detection and point-of-care testing in the past few decades. The surface nanotopography of a solid substrate is a dominant parameter in the efficiency of antibody immobilization, but precise control over surface roughness has not been fully investigated. Here we presented lateral flow immunoassay platforms with nanometer-scale surface roughness, reproducibly engineered using thermal nanoimprinting lithography, and investigated the effects of surface nanotopography on immunoadsorption and immunoassay performance. We fabricated three types of imprinted polycarbonate sheets with microcone array structures having different degrees of surface roughness using three types of molds fabricated by micromachining or laser ablation. The structures fabricated by laser-ablated nickel mold exhibited numerous bumps measuring several tens of nanometers, which enhanced antibody adsorption. We performed sandwich immunoassays of C-reactive protein in serum samples and achieved highly sensitive detection with a detection limit of ∼0.01 µg mL-1 and a broad dynamic range. The present results provide useful information on the remarkable effect of nanoengineered surfaces on biomolecule adsorption, and the platforms presented here will widen the applicability and versatility of lateral flow immunoassay devices.


Asunto(s)
Proteína C-Reactiva/química , Inmunoensayo/instrumentación , Nanoestructuras , Polímeros/química , Adsorción , Bioensayo/métodos , Inmunoensayo/métodos , Límite de Detección , Propiedades de Superficie
14.
Micromachines (Basel) ; 10(6)2019 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-31242547

RESUMEN

We herein propose a new hydrodynamic mechanism of particle separation using dual-depth, lattice-patterned asymmetric microchannel networks. This mechanism utilizes three-dimensional (3D) laminar flow profiles formed at intersections of lattice channels. Large particles, primarily flowing near the bottom surface, frequently enter the shallower channels (separation channels), whereas smaller particles flowing near the microchannel ceiling primarily flow along the deeper channels (main channels). Consequently, size-based continuous particle separation was achieved in the lateral direction in the lattice area. We confirmed that the depth of the main channel was a critical factor dominating the particle separation efficiencies, and the combination of 15-µm-deep separation channels and 40-µm-deep main channels demonstrated the good separation ability for 3-10-µm particles. We prepared several types of microchannels and successfully tuned the particle separation size. Furthermore, the input position of the particle suspension was controlled by adjusting the input flow rates and/or using a Y-shaped inlet connector that resulted in a significant improvement in the separation precision. The presented concept is a good example of a new type of microfluidic particle separation mechanism using 3D flows and may potentially be applicable to the sorting of various types of micrometer-sized objects, including living cells and synthetic microparticles.

15.
Lab Chip ; 19(10): 1828-1837, 2019 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-30998230

RESUMEN

Even though a number of microfluidic systems for particle/cell sorting have been proposed, facile and versatile platforms that provide sufficient sorting throughput and good operability are still under development. Here we present a simple but effective numbering-up strategy to dramatically increase the throughput of a continuous-flow particle/cell sorting scheme based on hydrodynamic filtration (HDF). A microfluidic channel equipped with multiple branches has been employed as a unit structure for size-based filtration, which realizes precise sorting without necessitating sheath flows. According to the concept of resistive circuit models, we designed and fabricated microdevices incorporating 64 or 128 closely assembled, multiplied units with a separation size of 5.0/7.0 µm. In proof-of-concept experiments, we successfully separated single micrometer-sized model particles and directly separated blood cells (erythrocytes and leukocytes) from blood samples. Additionally, we further increased the unit numbers by laminating multiple layers at a processing speed of up to 15 mL min-1. The presented numbering-up strategy would provide a valuable insight that is universally applicable to general microfluidic particle/cell sorters and may facilitate the actual use of microfluidic systems in biological studies and clinical diagnosis.


Asunto(s)
Separación Celular/instrumentación , Ensayos Analíticos de Alto Rendimiento , Hidrodinámica , Técnicas Analíticas Microfluídicas/instrumentación , Voluntarios Sanos , Humanos , Tamaño de la Partícula
16.
Analyst ; 144(5): 1519-1526, 2019 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-30539188

RESUMEN

Although various types of on-site immunoassay platforms have been developed, facile and reliable sample-to-answer immunoassay systems are still under development. In this study, we proposed a lateral-flow immunoassay system utilizing a polymer sheet with microcone array structures fabricated by thermal imprinting. By adding a surfactant to the running/washing buffer, we were able to dispense with complicated chemical modification protocols, which are usually necessary to enhance antibody adsorption. We investigated three types of polymeric materials and confirmed that polycarbonate is most suitable as an imprinted polymer substrate. Experiments using microcone arrays with different distances revealed that the increased surface area with nanometer-scale surface roughness was key to achieving stable immobilization of antibodies. To assess the applicability of this assay to clinical diagnosis, C-reactive protein in a pure buffer and in a serum sample was analyzed as a model, with a ∼0.1 µg mL-1 lower limit of detection. The presented approach would open a new path to the development of immunoassay-based on-site point-of-care testing by virtue of its simplicity of operation, high sensitivity, and versatility.


Asunto(s)
Proteína C-Reactiva/análisis , Inmunoensayo/métodos , Adsorción , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Biomarcadores/análisis , Proteína C-Reactiva/inmunología , Humanos , Inmunoensayo/instrumentación , Límite de Detección , Cemento de Policarboxilato/química , Polimetil Metacrilato/química , Propiedades de Superficie , Tensoactivos/química , Temperatura
17.
ACS Appl Bio Mater ; 2(5): 2237-2245, 2019 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-35030662

RESUMEN

With the recent progress in three-dimensional (3D) cell culture techniques for regenerative medicine and drug development, hydrogel-based tissue engineering approaches that can precisely organize cells into functional formats have attracted increasing attention. However, challenges remain in creating continuous microconduits within hydrogels to effectively deliver oxygen and nutrients to the embedded cells. Here we propose a one-step, fully liquid state, and all-aqueous process to create porous hydrogels that can encapsulate living cells without the need for extensive processing protocols, including the incorporation and removal of sacrificial materials. An unusual bicontinuous state of aqueous two-phase dispersion was utilized, and one of the two phases, encapsulating living cells, was rapidly photo-cross-linked to form hydrogel sponges. We optimized the volumetric mixing ratio of gelatin methacrylate (GelMA)-rich and polyethylene glycol (PEG)-rich solutions and investigated the effects of the formed continuous microconduits on the cell functions by creating liver-tissue mimetic 3D constructs. The presented technology provides a facile and versatile strategy for fabricating microstructured hydrogels for cell culture and would bring new insights for the development of porous materials by fully aqueous bicontinuous dispersions.

18.
RSC Adv ; 9(16): 9136-9144, 2019 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35517655

RESUMEN

Vascular tissue models created in vitro are of great utility in the biomedical research field, but versatile, facile strategies are still under development. In this study, we proposed a new approach to prepare vascular tissue models in PDMS-based composite channel structures embedded with barium salt powders. When a cell-containing hydrogel precursor solution was continuously pumped in the channel, the precursor solution in the vicinity of the channel wall was selectively gelled because of the barium ions as the gelation agent supplied to the flow. Based on this concept, we were able to prepare vascular tissue models, with diameters of 1-2 mm and with tunable morphologies, composed of smooth muscle cells in the hydrogel matrix and endothelial cells on the lumen. Perfusion culture was successfully performed under a pressurized condition of ∼120 mmHg. The presented platform is potentially useful for creating vascular tissue models that reproduce the physical and morphological characteristics similar to those of vascular tissues in vivo.

19.
Lab Chip ; 18(9): 1378-1387, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29658964

RESUMEN

Cell migration and invasion are of significant importance in physiological phenomena, including wound healing and cancer metastasis. Here we propose a new system for quantitatively evaluating cancer cell invasion in a three-dimensional (3D), in vivo tissue-like environment. This system uses composite hydrogel microfibers whose cross section has a relatively soft micropassage region and that were prepared using a multilayered microfluidic device; cancer cells are encapsulated in the core and fibroblasts are seeded in the shell regions surrounding the core. Cancer cell proliferation is guided through the micropassage because of the physical restriction imposed by the surrounding solid shell regions. Quantitative analysis of cancer cell invasion is possible simply by counting the cancer cell colonies that form outside the fiber. This platform enables the evaluation of anticancer drug efficacy (cisplatin, paclitaxel, and 5-fluorouracil) based on the degree of invasion and the gene expression of cancer cells (A549 cells) with or without the presence of fibroblasts (NIH-3T3 cells). The presented hydrogel fiber-based migration assays could be useful for studying cell behaviors under 3D coculture conditions and for drug screening and evaluation.


Asunto(s)
Movimiento Celular/fisiología , Técnicas de Cocultivo/instrumentación , Hidrogeles/química , Técnicas Analíticas Microfluídicas/instrumentación , Invasividad Neoplásica/fisiopatología , Células A549 , Animales , Diseño de Equipo , Humanos , Ratones , Células 3T3 NIH
20.
J Biosci Bioeng ; 126(1): 111-118, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29502942

RESUMEN

Although the reconstruction of functional 3D liver tissue models in vitro presents numerous challenges, it is in great demand for drug development, regenerative medicine, and physiological studies. Here we propose a new approach to perform perfusion cultivation of liver cells by assembling cell-laden hydrogel microfibers. HepG2 cells were densely packed into the core of sandwich-type anisotropic microfibers, which were produced using microfluidic devices. The obtained microfibers were bundled up and packed into a perfusion chamber, and perfusion cultivation was performed. We evaluated cell viability and functions, and also monitored the oxygen consumption. Furthermore, fibers covered with vascular endothelial cells were united during the perfusion culture, to form vascular network-like conduits between fibers. The presented technique can structurally mimic the hepatic lobule in vivo and could prove to be a useful model for various biomedical research applications.


Asunto(s)
Técnicas de Cultivo de Célula , Hepatocitos/citología , Hígado/citología , Ingeniería de Tejidos/instrumentación , Ingeniería de Tejidos/métodos , Animales , Bovinos , Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Células Cultivadas , Técnicas de Cocultivo , Células Endoteliales/citología , Células Hep G2 , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Dispositivos Laboratorio en un Chip , Microtecnología/instrumentación , Microvasos/citología , Perfusión , Medicina Regenerativa/instrumentación , Medicina Regenerativa/métodos , Andamios del Tejido
SELECCIÓN DE REFERENCIAS